The Hennig MistFlow comes in three sizes and has been engineered for high pressure coolant and mist applications. It’s a compact solution with multi-stage filtration (including HEPA), featuring a baffled side inlet which helps to extend intervals between cleaning the washable filter stages. Accumulated coolant drains back to the machine using a separate drain port. Directly mount your MistFlow to your UltraFlow, VariFlow, or EcoFlow for a clean factory look, or use one of our universal stands and hose for a simple and easy installation directly on the machine tool enclosure.
| Features |
| Multi-Stage Filtration |
Stage 1: Baffle Filter (Washable) Stage 2: Mesh Filter (Washable) Stage 3: HEPA |
| Install Location Options |
On Hennig high-pressure coolant systems. Directly on the machine tool. Floor-mounted next to the machine tool (400, 800). |
| 115 or 220 VAC, Single-Phase |
|
| Filter Restriction Monitor |
|
| Status Light |
Incorporated into the logo: Blue: Power On (Idle) Green: Power On (Running) Red: Power On (Thermal Overload Trip) |
| System Specifications |
|
| System |
400 |
800 |
1200 |
| CFM |
400 |
800 |
1200 |
| Dimensions* (in) |
22.5 x 17 x 24.5 |
26.5 x 20 x 27.5 |
31.5 x 26 x 35 |
| Hose Size |
6" |
6" or 8" |
10" |
| Working envelope - open air volume (up to)** |
125 ft3 |
250 ft3 |
375 ft3 |
*Includes electrical box on the back of the enclosure.
**Recommended enclosure size is estimated using a Changeover Factor of 4 - for heavy mist or fog, a higher Changeover Factor of 5 to 8 is recommended, go up a MistFlow size in those situations.